DS30
The alarm
levelscan then be set to a percentage or factor above this background reference
level. A digital display (#) displays the percentage of dust in relation to the
alarm level, having a span of 0-200% of the chosen alarm level setting. The
4-20mA output is scaled 0-200% of alarm level 1, allowing the operator to
determine how the dust level is compared to a pre-determined limit or warning
level.
The two
alarm levels can be used to set both warning and emission limit levels to
assist operators in potential failures from their arrestment plant.
Alarm delay
and data averaging are user selectable. The DS30 series complies with the UK
EPA requirement for indicative monitoring andEuropean requirements for filter
performance monitoring. .
Dust monitoring/In-situ/Bagfilter Management Systems/DS30