MA-2000 Series Mercury Analyzers

The absolute best and most versatile combustion mercury analyzer available! Whether you simply need a combustion-based mercury analyzer for single sample analysis in 5 minutes according to EPA Method SW-846 7473, automated analysis with a 32-position autosampler for solids, liquids, and gases, or you prefer to be able to perform all of this in addition to EPA Methods 1631E, 245.1, 245.2, 245.5, and 245.7 on one instrument, the MA-2000 is the right choice for you. It is the only mercury analyzer available that is capable of performing all of these methods on one platform. As with every mercury analyzer from Nippon Instruments Corporation, the MA-2000 requires absolutely no compressed gases!

Key Benefits

bullet

Capable of performing EPA Methods SW-846 7473, 245.1, 245.2, 245.5, 245.7, and 1631E all on one platform!

bullet

Requires no compressed gases for operation, producing its own zero-grade carrier gas internally.

bullet

Sensitivity down to 0.005 ng Hg for combustion and even lower for reducing vaporization.

bullet

Compliant with EPA Method 1631E (0.5 to 100 ppt Hg).

bullet

No sample digestion required with combustion configuration.

bullet

Capable of analyzing any sample type (solid, liquid, and gas).

bullet

Extremely reliable and produces outstanding quality of data.

 

The model MA-2000 is intended for heat-vaporizing mercury present in a sample and then collecting it as a gold amalgam for measurement. This model does not require any wet pretreatment of samples, and hence can easily measure solid and liquid samples in as short a time as five minutes per sample. Both the control and data processing software are compatible with Windows, and labor-saving is achieved with the automatic sample changer.

Model MA-2
Model MA-2000
Model MA-2010
PAGE TOP
Specifications
Heat-vaporization mercury measuring equipment (MA-2)
Pretreatment unit
Sample: Solid, liquid, gaseous (Collecting tube used)
Carrier gas: Cleaned air
Combustion tube: Ceramic
Sample boat: Ceramic (10 supplied)
Heating temperature: 900°C or above

Detection unit
Measurement principle: Non-dispersive double-beam cold-vapor atomic absorption
Wavelength: 253.7 nm
Lower detection limit: 0.002 ng
Measuring range: Max. 1000 ng

Control and data processing system (PC-Win/M-A2)
OS: Windows2000/XP
Display: Peak wave form, calibration curve graph, measurement results, measuring status
Control:
Decomposition: Heating temperature, time
Measurement: Measuring object, start/stop, time
Processing: Calibration curve, unit setting, concentration calculation, baseline correction, statistical calculations
Printable items: Memo, calibration diagram and expressions, measurement table, statistical calculations, peak wave form
Accuracy control: Standard check, blank check
Options
For heat-vaporization measurement
Automatic sample changer (BC-1)
Sample Q’ty: 32 & 40 samples
Sample carry-in unit: Measure against external pollution (maintains positive pressure)

For reducing-vaporization measurement
Reducing-vaporization unit (S-MA)
Sample container: 20 mL

Reagent dispensing burette (RD-3)
Dispensed liquid: Sulfuric acid, stannous chloride solution, distilled water

Automatic sample changer (SC-3)
Sample Q’ty: 60 positions
Sample container: 5 mL

For atmospheric mercury measurement
Mercury collecting tube bake out oven unit (RH-MA)
Heating method: Anti-pollution heating method