The
transmitter model Messenger is required to use this sensor. The system has been
designed for continuous operation with long life time. A ratio measurement of
direct- / scatter light assure highly reliable and repeatable measurement
results. Inaccuracies caused by product colour, lamp ageing or window coating
will be compensated. The forward scatter measuring results are nearly
independent of particle size and will correlate to product concentration.
Calibration can be done in multiple ranges and measurement units like EBC, ppm,
mg/l, etc.. The sensors can be installed into almost any type of pipe. Process
connection, pressure, temperature, gasket material, etc will be application
specific. Optional cleaning jets will allow a cleaning of the sapphire windows
in determined intervals.
Applications:
Operational areas:
• Filtration
control
• Chemical industry
• Product
quality
• Petrochemical industry
• Water in
fuel
• Power plants
• Oil in water / Water in
oil
• Brew & Beverage