Artikel/Pagina Bijlagen (1) Artikel (0) Informatie aanvraag
Rotational viscometers (Brookfield methode)

Viscometers RC01 / RC02

for fast viscosity measurements (Brookfield method)

The RheoTec models RC01 and RC02 are rotational viscometers for easy and fast viscosity determination as specified in ISO 2555 and other ASTM standards.

These standards define a viscometer to be used in torque, rotational speed and spindle design. The viscometers RC01 / RC02 (versions L or R) comply with the provided instrument specifications and are therefore 100% compatible to the Brookfield method.

These instruments with an easy-to-clean geometry give the opportunity to do precise and time-saving single point measurements in daily routine as well as to perform advanced viscosity determinations in research and development.

Special Features

  • clear keypad allows a simple menu navigation
  • digital display for direct reading of diverse parameters
  • complete Brookfield spindle set (torque range versions L or R)
  • temperature sensor Pt100 for flexible installation
  • warning signal of under- or over-range condition
  • interface RS232 for data transfer to PC
  • bidirectional interface RS232 for RC02 control and PC data evaluation
  • robust carrying case for viscometer and standard accessories (incl. spindle rack, spindle guard and manual)

Requirements

mains

100 to 240 V / 50 to 60 Hz

room temperature

10° C to 40° C

relative humidity

< 80%

 

Display Parameters

rotational speed

rpm

spindle no. (used geometry)

S.P.

dynamic viscosity

mPas or cP

scale (Brookfield)

%

sample temperature

° C or ° F

auto range (max. viscosity)

mPas or cP

shear rate S.R.

1/sec

shear stress S.S.

N/m2 or dyne/cm2 (at RC02 models)

 

Specifications

rotational speeds

 0.3 - 0.5 - 0.6 - 1 - 1.5 - 2 - 2.5 - 3 - 4 - 5 - 6 - 10 - 12 - 20 - 30 - 50 - 60 - 100 - 200 rpm

accuracy:

> 0.5% of absolute value


spindles

version L:

4 spindles (L1 - L2 - L3 - L4)

version R:

6 spindles (R2 - R3 - R4 - R5 - R6 - R7)


viscosity ranges

version L:

3 - 2,000,000 mPas in 76 ranges 19 speeds with 4 spindles (for low to medium viscosity test fluids)

version R:

20 - 13,000,000 mPas in 114 ranges 19 speeds with 6 spindles (for medium to high viscosity test fluids)

accuracy:

± 1% of full scale

repeatability:

± 0.2%


temperature sensor

temperature range:

-15° C to +180° C (5° F to 356° F)

resolution:

0.1° C (0.1722° F)

accuracy:

± 0.1° C

Optional Accessories

  • Adapter for Small Sample Volumes
  • Adapter for Low Viscosity Materials
  • Helipath stand
  • software VISCOSOFT BASIC (measurement presentation, data evaluation)
  • software RHEOSOFT PLUS (viscometer control, data mangement)


 


Memory: 1499Copyright: Ankersmid 2009 Contact: info@ankersmid.com